Delta VFD-C200 Series Compact High-End Vector Inverter
PRODUKTPARAMETER
- Energy-saving: reduces power consumption efficiently
- High performance: precise vector control for multiple motor types
- Durable design: long-life components with enhanced protection
- Flexible integration: supports MODBUS and CAN bus communication
Beschreibung
PRODUKTMERKMALE
The Delta VFD-C200 Series is a new generation compact high-end vector inverter designed to deliver precise motor control for a wide range of industrial applications. Its innovative anti-dust and heat dissipation design ensures reliable performance even in harsh environments.
Equipped with advanced vector control, the VFD-C200 supports multiple motor control modes and offers high flexibility for different industrial applications. The series also integrates PG card compatibility for closed-loop vector control and strong open-loop vector performance.
With a focus on durability, the VFD-C200 features long-life components and enhanced environmental protection. Standard MODBUS and CAN bus communication capabilities allow easy integration into industrial automation systems, ensuring efficient operation and reduced downtime.
ANWENDUNGSBEREICHE
| Application Areas | ||
|---|---|---|
| Food Packaging Machine | Conveyor Equipment | Textile Machine |
| Woodworking Machine | Fan | Water Pump |
TECHNISCHE DATEN
| 230V | Frame | Model VFD-CB2_A- | Single-phase A0 (Frame) | Single-phase A0 (Frame) | Single-phase A0 (Frame) | Single-phase A0 (Frame) | Three-phase A0 (Frame) | Three-phase A0 (Frame) | Three-phase A0 (Frame) | Three-phase A0 (Frame) | Three-phase A0 (Frame) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Frame No. | 004 | 007 | 015 | 022 | 004 | 007 | 015 | 022 | 037 | ||
| Output – Normal Load | Applicable Motor Power (kW) | 0.4 | 0.75 | 1.5 | 2.2 | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | |
| Applicable Motor Power (HP) | 0.5 | 1 | 2 | 3 | 0.5 | 1 | 2 | 3 | 5 | ||
| Rated Output Capacity (kVA) | 1.2 | 2.0 | 3.2 | 4.4 | 1.2 | 2.0 | 3.2 | 4.4 | 6.8 | ||
| Rated Output Current (A) | 3 | 5 | 8 | 11 | 3 | 5 | 8 | 11 | 17 | ||
| Overload Tolerance | (Uniform) 120% of rated output current for 1 min; 160% for 3 sec | ||||||||||
| Maximum Output Frequency (Hz) | (Uniform) 600.00Hz | ||||||||||
| Carrier Frequency (kHz) | (Uniform) 2~15kHz (Factory setting: 8kHz) | ||||||||||
| Output – Heavy Load | Rated Output Capacity (kVA) | 1.1 | 1.9 | 2.8 | 4.0 | 1.1 | 1.9 | 2.8 | 4.0 | 6.4 | |
| Rated Output Current (A) | 2.8 | 4.8 | 7.1 | 10 | 2.8 | 4.8 | 7.1 | 10 | 16 | ||
| Overload Tolerance | (Uniform) 150% of rated output current for 1 min; 180% for 3 sec | ||||||||||
| Maximum Output Frequency (Hz) | (Uniform) 300.00Hz | ||||||||||
| Carrier Frequency (kHz) | (Uniform) 2~15kHz (Factory setting: 2kHz) | ||||||||||
| Input | Input Current (A) Normal Load | 7.2 | 12 | 15.7 | 22 | 3.9 | 6.4 | 12 | 16 | 20 | |
| Input Current (A) Heavy Load | 6.7 | 11.5 | 14 | 20 | 3.6 | 6.1 | 11 | 15 | 18.5 | ||
| Rated Voltage/Frequency | (Uniform) Single-phase/Three-phase AC 200V–240V (-15%~+10%), 50/60Hz | ||||||||||
| Operating Voltage Range | (Uniform) 170~265Vac | ||||||||||
| Allowable Power Frequency Variation | (Uniform) 47~63Hz | ||||||||||
| Cooling Method | Natural Air Cooling | Forced Air Cooling | – | – | Natural Air Cooling | – | – | Forced Air Cooling | – | ||
| Brake Chopper | (Uniform) Built-in |
| 460V | Frame | Model VFD___CB43A___ | Frame No. | 007 | 015 | 022 | 037 | 040 | 055 | 075 |
|---|---|---|---|---|---|---|---|---|---|---|
| Output – Normal Load | Applicable Motor Power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 4.0 | 5.5 | 7.5 | ||
| Applicable Motor Power (HP) | 1 | 2 | 3 | 5 | 5.5 | 7.5 | 10 | |||
| Rated Output Capacity (kVA) | 2.4 | 3.2 | 4.8 | 7.2 | 8.4 | 10 | 14 | |||
| Rated Output Current (A) | 3.0 | 4.0 | 6.0 | 9.0 | 10.5 | 12 | 18 | |||
| Overload Tolerance | Uniform | 120% of rated output current for 1 min; 160% for 3 sec | ||||||||
| Maximum Output Frequency (Hz) | Uniform | 600.00Hz | ||||||||
| Carrier Frequency (kHz) | Uniform | 2~15kHz (Factory setting: 8kHz) | ||||||||
| Output – Heavy Load | Rated Output Capacity (kVA) | 2.3 | 3.0 | 4.5 | 6.5 | 7.6 | 9.6 | 14 | ||
| Rated Output Current (A) | 2.9 | 3.8 | 5.7 | 8.1 | 9.5 | 11 | 17 | |||
| Overload Tolerance | Uniform | 150% of rated output current for 1 min; 180% for 3 sec | ||||||||
| Maximum Output Frequency (Hz) | Uniform | 300.00Hz | ||||||||
| Carrier Frequency (kHz) | Uniform | 2~15kHz (Factory setting: 2kHz) | ||||||||
| Input | Input Current (A) Normal Load | 4.3 | 5.9 | 8.7 | 14 | 15.5 | 17 | 20 | ||
| Input Current (A) Heavy Load | 4.1 | 5.6 | 8.3 | 13 | 14.5 | 16 | 19 | |||
| Rated Voltage/Frequency | Uniform | Three-phase AC 380V~480V (-15%~+10%), 50/60Hz | ||||||||
| Operating Voltage Range | Uniform | 323~528Vac | ||||||||
| Allowable Power Frequency Variation | Uniform | 47~63Hz | ||||||||
| Cooling Method | Natural Air Cooling | – | – | – | – | Forced Air Cooling | – | |||
| Brake Chopper | Uniform | Eingebaut | ||||||||
| Note | *… indicates models -20/-21/-211, etc. |
FAQs
Als integriertes Handels- und Produktionsunternehmen bieten wir eine vollständige Palette von Delta-Stromversorgungen an, darunter Schaltnetzteile, industrielle Stromversorgungsmodule und geregelte Gleichstromversorgungen, die für die industrielle Automatisierung und verschiedene elektronische Geräte geeignet sind.
Ja. Wir bieten maßgeschneiderte Lösungen auf der Grundlage der Kundenanforderungen, einschließlich Spannung, Leistung und Funktionserweiterungen, mit professioneller technischer Unterstützung, um die Machbarkeit zu gewährleisten.
Der Versand erfolgt über zuverlässige Logistik- und Kurierdienste, die eine lückenlose Nachverfolgung anbieten, um sicherzustellen, dass die Produkte sicher und pünktlich beim Kunden ankommen.
Das Verfahren ist einfach: Modell auswählen → Anforderungen einreichen → Lösung bestätigen → Zahlung vereinbaren → Lieferung und technische Beratung. Wir bieten umfassende Unterstützung, damit jeder Schritt reibungslos abläuft.
Wir bieten Original-Herstellergarantie, Ersatzteilversorgung, Betriebsanleitung, Wartung und Fehlerbehebung, um einen stabilen und zuverlässigen Betrieb der Delta-Netzteile zu gewährleisten.