PRODUCT PARAMETERS
- Output frequency 0.1–600 Hz
- Robust PDFF servo control
- Zero-speed, high-speed, and low-speed PI gain and frequency bandwidth settings
Description
PRODUCT FEATURES
The Delta VFD-VE Series Inverter offers a wide output frequency range from 0.1 to 600 Hz and features robust PDFF servo control. It allows zero-speed, high-speed, and low-speed PI gain and frequency bandwidth settings, ensuring precise torque even at zero speed.
With overload capacity up to 150% for one minute and 200% for two seconds, the series supports origin return, pulse following, and 16-point point-to-point position control. It provides position, speed, and torque control modes, strong tension management, and winding/unwinding functions, making it ideal for complex industrial applications.
Equipped with a 32-bit high-speed CPU capable of outputting up to 3333.4 Hz, dual RS-485 support, fieldbus connectivity, spindle positioning, high-speed electric spindle drive, rigid tapping capability, and Windows PC monitoring software for dynamic parameter management, the VFD-VE Series delivers flexible, high-performance solutions for advanced industrial machinery.
APPLICATION FIELDS
| ELEVATOR | OVERHEAD CRANE | HOIST |
|---|---|---|
| PCB DRILLING MACHINE | ENGRAVING MACHINE | STEEL & METALLURGY |
| PETROLEUM | CNC MACHINE TOOL | INJECTION MOLDING MACHINE |
| AUTOMATED STORAGE SYSTEM | PRINTING MACHINERY | REWINDING MACHINE |
| SLITTING MACHINE |
TECHNICAL SPECIFICATIONS
230V Series
| Voltage Level | 230V Class | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 185 | 220 | 220 | 300 | 370 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Output Control | Model VFD-XXXV | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 185 | 220 | 220 | 300 | 370 |
| Output Control | Rated Output Power (kVA) | 1.9 | 2.7 | 4.2 | 6.5 | 9.5 | 13 | 19 | 29 | 34 | 34 | 46 | 55 |
| Output Control | Rated Output Current (A) | 5.0 | 7.5 | 11 | 17 | 25 | 33 | 49 | 75 | 90 | 90 | 120 | 146 |
| Output Control | Applicable Motor Power (kW) | 1.0 | 2.0 | 3.0 | 5.0 | 7.5 | 10 | 15 | 25 | 30 | 30 | 40 | 50 |
| Output Control | Applicable Motor Power (HP) | 1.0 | 2.0 | 3.0 | 5.0 | 7.5 | 10 | 15 | 25 | 30 | 30 | 40 | 50 |
| Output Control | Transformer Output Current (A) | 6.25 | 9.6 | 13 | 21 | 31 | 45 | 61 | 93 | 112 | 112 | 150 | 182 |
| Output Control | Applicable Motor Power (HP) | 1.5 | 2.5 | 4 | 7.5 | 10 | 15 | 20 | 30 | 40 | 40 | 50 | 60 |
| Output Control | Maximum Output Voltage (V) | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage |
| Output Control | Output Frequency Range (Hz) | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz |
| Output Control | Input Current (A) | 6.4 | 9.9 | 15 | 21 | 25 | 33 | 49 | 63 | 68 | 79 | 106 | 125 |
| Output Control | Allowable Input Voltage | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz |
| Output Control | Allowable Input Voltage Variation | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) |
| Output Control | Allowable Power Frequency Variation | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) |
| Output Control | Cooling Method | Natural Air Cooling | Natural Air Cooling | Natural Air Cooling | Natural Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling |
| Output Control | Weight (kg) | 2.7 | 3.2 | 4.5 | 6.8 | 8 | 10 | 13 | 13 | 13 | 13 | 36 | 36 |
460V Series
| 460V Series | Voltage Level | 460V Class | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 150 | 185 | 220 | 300 | 370 | 450 | 550 | 750 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Output | Model VFD-XXXV | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 150 | 185 | 220 | 300 | 370 | 450 | 550 | 750 | |
| Output | Rated Output Power (kVA) | 2.3 | 3.2 | 4.2 | 6.3 | 9.9 | 14 | 18 | 24 | 29 | 34 | 48 | 56 | 69 | 80 | 100 | |
| Output | Rated Output Current (A) | 3.0 | 4.2 | 6.0 | 8.5 | 13 | 18 | 24 | 32 | 38 | 45 | 60 | 73 | 91 | 110 | 150 | |
| Output | Applicable Motor Power (HP) | 1.0 | 2.0 | 3.0 | 5.0 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | |
| Output | Transformer Output Current (A) | 3.8 | 5.3 | 7.5 | 10 | 18 | 22 | 30 | 40 | 47 | 56 | 75 | 91 | 113 | 138 | 188 | |
| Output | Applicable Motor Power (HP) | 1.5 | 2.5 | 4 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | 125 | |
| Output | Maximum Output Voltage (V) | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | |
| Output | Output Frequency Range (Hz) | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | |
| Power | Input Current (A) | Three-phase 380~480V | 4.0 | 5.8 | 7.4 | 9.9 | 12 | 17 | 25 | 27 | 35 | 42 | 56 | 67 | 87 | 101 | 122 |
| Power | Allowable Input Voltage | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | |
| Power | Allowable Input Voltage Variation | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | |
| Power | Allowable Power Frequency Variation | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | |
| Power | Cooling Method | Natural Air Cooling | Natural Air Cooling | Natural Air Cooling | Natural Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | |
| Power | Weight (kg) | 2.7 | 3.2 | 4.5 | 6.8 | 8 | 10 | 13 | 13 | 13 | 13 | 36 | 36 | 36 | 50 | 50 |
FAQs
As a trade-and-manufacturing integrated company, we offer a full range of Delta power supplies, including switching power supplies, industrial power modules, and DC regulated power supplies, suitable for industrial automation and various electronic equipment.
Yes. We provide customized solutions based on customer requirements, including voltage, power, and functional extensions, with professional technical support to ensure feasibility.
We ship via reliable logistics and courier services, offering full tracking to ensure the products reach customers safely and on time.
The process is simple: select the model → submit requirements → confirm the solution → arrange payment → delivery and technical guidance. We provide full support to ensure each step is completed smoothly.
We provide original manufacturer warranty, spare parts supply, operation guidance, maintenance, and troubleshooting services to ensure Delta power supplies operate stably and reliably.