Delta VFD-VE Series Inverter
PARAMETRI DEL PRODOTTO
- Output frequency 0.1–600 Hz
- Robust PDFF servo control
- Zero-speed, high-speed, and low-speed PI gain and frequency bandwidth settings
Descrizione
CARATTERISTICHE DEL PRODOTTO
The Delta VFD-VE Series Inverter offers a wide output frequency range from 0.1 to 600 Hz and features robust PDFF servo control. It allows zero-speed, high-speed, and low-speed PI gain and frequency bandwidth settings, ensuring precise torque even at zero speed.
With overload capacity up to 150% for one minute and 200% for two seconds, the series supports origin return, pulse following, and 16-point point-to-point position control. It provides position, speed, and torque control modes, strong tension management, and winding/unwinding functions, making it ideal for complex industrial applications.
Equipped with a 32-bit high-speed CPU capable of outputting up to 3333.4 Hz, dual RS-485 support, fieldbus connectivity, spindle positioning, high-speed electric spindle drive, rigid tapping capability, and Windows PC monitoring software for dynamic parameter management, the VFD-VE Series delivers flexible, high-performance solutions for advanced industrial machinery.
APPLICATION FIELDS
| ELEVATOR | OVERHEAD CRANE | HOIST |
|---|---|---|
| PCB DRILLING MACHINE | ENGRAVING MACHINE | STEEL & METALLURGY |
| PETROLEUM | CNC MACHINE TOOL | INJECTION MOLDING MACHINE |
| AUTOMATED STORAGE SYSTEM | PRINTING MACHINERY | REWINDING MACHINE |
| SLITTING MACHINE |
SPECIFICHE TECNICHE
230V Series
| Voltage Level | 230V Class | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 185 | 220 | 220 | 300 | 370 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Output Control | Model VFD-XXXV | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 185 | 220 | 220 | 300 | 370 |
| Output Control | Rated Output Power (kVA) | 1.9 | 2.7 | 4.2 | 6.5 | 9.5 | 13 | 19 | 29 | 34 | 34 | 46 | 55 |
| Output Control | Rated Output Current (A) | 5.0 | 7.5 | 11 | 17 | 25 | 33 | 49 | 75 | 90 | 90 | 120 | 146 |
| Output Control | Applicable Motor Power (kW) | 1.0 | 2.0 | 3.0 | 5.0 | 7.5 | 10 | 15 | 25 | 30 | 30 | 40 | 50 |
| Output Control | Applicable Motor Power (HP) | 1.0 | 2.0 | 3.0 | 5.0 | 7.5 | 10 | 15 | 25 | 30 | 30 | 40 | 50 |
| Output Control | Transformer Output Current (A) | 6.25 | 9.6 | 13 | 21 | 31 | 45 | 61 | 93 | 112 | 112 | 150 | 182 |
| Output Control | Applicable Motor Power (HP) | 1.5 | 2.5 | 4 | 7.5 | 10 | 15 | 20 | 30 | 40 | 40 | 50 | 60 |
| Output Control | Maximum Output Voltage (V) | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage |
| Output Control | Output Frequency Range (Hz) | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz |
| Output Control | Input Current (A) | 6.4 | 9.9 | 15 | 21 | 25 | 33 | 49 | 63 | 68 | 79 | 106 | 125 |
| Output Control | Allowable Input Voltage | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz |
| Output Control | Allowable Input Voltage Variation | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) |
| Output Control | Allowable Power Frequency Variation | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) |
| Output Control | Cooling Method | Natural Air Cooling | Natural Air Cooling | Natural Air Cooling | Natural Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling |
| Output Control | Weight (kg) | 2.7 | 3.2 | 4.5 | 6.8 | 8 | 10 | 13 | 13 | 13 | 13 | 36 | 36 |
460V Series
| 460V Series | Voltage Level | 460V Class | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 150 | 185 | 220 | 300 | 370 | 450 | 550 | 750 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Output | Model VFD-XXXV | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 150 | 185 | 220 | 300 | 370 | 450 | 550 | 750 | |
| Output | Rated Output Power (kVA) | 2.3 | 3.2 | 4.2 | 6.3 | 9.9 | 14 | 18 | 24 | 29 | 34 | 48 | 56 | 69 | 80 | 100 | |
| Output | Rated Output Current (A) | 3.0 | 4.2 | 6.0 | 8.5 | 13 | 18 | 24 | 32 | 38 | 45 | 60 | 73 | 91 | 110 | 150 | |
| Output | Applicable Motor Power (HP) | 1.0 | 2.0 | 3.0 | 5.0 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | |
| Output | Transformer Output Current (A) | 3.8 | 5.3 | 7.5 | 10 | 18 | 22 | 30 | 40 | 47 | 56 | 75 | 91 | 113 | 138 | 188 | |
| Output | Applicable Motor Power (HP) | 1.5 | 2.5 | 4 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | 125 | |
| Output | Maximum Output Voltage (V) | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | |
| Output | Output Frequency Range (Hz) | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | |
| Power | Input Current (A) | Three-phase 380~480V | 4.0 | 5.8 | 7.4 | 9.9 | 12 | 17 | 25 | 27 | 35 | 42 | 56 | 67 | 87 | 101 | 122 |
| Power | Allowable Input Voltage | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | |
| Power | Allowable Input Voltage Variation | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | |
| Power | Allowable Power Frequency Variation | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | |
| Power | Cooling Method | Natural Air Cooling | Natural Air Cooling | Natural Air Cooling | Natural Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | |
| Power | Weight (kg) | 2.7 | 3.2 | 4.5 | 6.8 | 8 | 10 | 13 | 13 | 13 | 13 | 36 | 36 | 36 | 50 | 50 |
Domande frequenti
In qualità di azienda integrata di commercio e produzione, offriamo una gamma completa di alimentatori Delta, tra cui alimentatori switching, moduli di alimentazione industriali e alimentatori regolati in corrente continua, adatti all'automazione industriale e a varie apparecchiature elettroniche.
Sì. Forniamo soluzioni personalizzate in base alle esigenze del cliente, comprese le estensioni di tensione, potenza e funzionalità, con un supporto tecnico professionale per garantire la fattibilità.
Spediamo tramite servizi logistici e di corriere affidabili, offrendo una tracciabilità completa per garantire che i prodotti raggiungano i clienti in modo sicuro e puntuale.
Il processo è semplice: selezionare il modello → presentare i requisiti → confermare la soluzione → organizzare il pagamento → consegna e guida tecnica. Forniamo un'assistenza completa per garantire che ogni fase sia completata senza problemi.
Forniamo la garanzia del produttore originale, la fornitura di parti di ricambio, la guida al funzionamento, la manutenzione e i servizi di risoluzione dei problemi per garantire che gli alimentatori Delta funzionino in modo stabile e affidabile.