PARAMETRI DEL PRODOTTO

  • LCD keypad with built-in text display and TP Editor customizable interface
  • Quick setting functions for parameter copying and fast installation
  • Modular design with easy maintenance and expansion options
  • High-speed communication support including BACnet, RS-485, and optional cards
Descrizione
Domande frequenti
Richiesta di preventivo

Descrizione

CARATTERISTICHE DEL PRODOTTO

The Delta VFD-CP2000 Series features an LCD keypad with built-in text display, providing intuitive operation and quick learning. Combined with TP Editor software, users can customize the main interface for enhanced usability.

Quick setting functions allow users to copy parameter groups and perform fast, simple installation. The modular design ensures easy maintenance and future expansion. High-speed communication interfaces include BACnet and RS-485 (Modbus), with optional communication cards such as PROFIBUS DP, PROFINET, DeviceNet, Modbus TCP, EtherNet/IP, CANopen, and BACnet IP to meet diverse application needs.

Designed for long-term reliability, the CP2000 Series features coated PCBs for enhanced environmental resistance, fire mode and bypass functions for uninterrupted operation during emergencies, and versatile fan and pump control capabilities including PID control, sleep/wake functions, catch-up start, frequency hopping, multi-pump control, PLC with 10k steps, and real-time clock integration.

APPLICATION FIELDS

Application 1Application 2Application 3
Constant Pressure Water Pump (Fixed Volume / Timed Pump)Building Automation (BA)Factory Automation (FA)
HVAC DriveChilled Water PumpCooling Tower
General Motor Use

SPECIFICHE TECNICHE

ParameterFrame Size-A (007/015/022/037/055)Frame Size-B (075/110/150/185)Frame Size-C (220/300/370)Frame Size-D (450/550)Frame Size-E (750/900)
ModelVFDCP23-VFDCP23-VFDCP23-VFDCP23-VFDCP23-
Output – Light Load
Rated Output Capacity (kVA)2.0/3.0/4.0/6.0/8.412/18/24/3036/42/5872/86110/128
Rated Output Current (A)5/7.5/10/15/2131/46/61/7590/105/146180/215276/322
Applicable Motor Power (kW)0.75/1.5/2.2/3.7/5.57.5/11/15/18.522/30/3745/5575/90
Applicable Motor Power (HP)1/2/3/5/7.510/15/20/2530/40/5060/75100/125
Overload CapacityAcross columns: At 120% of rated output current, can withstand 1 min every 5 minAcross columns: At 120% of rated output current, can withstand 1 min every 5 minAcross columns: At 120% of rated output current, can withstand 1 min every 5 minAcross columns: At 120% of rated output current, can withstand 1 min every 5 minAcross columns: At 120% of rated output current, can withstand 1 min every 5 min
Max Output Frequency (Hz)599.00599.00599.00599.00400.00
Carrier Frequency (kHz)2~15 (preset 8)2~15 (preset 8)2~10 (preset 6)2~9 (preset 4)2~9 (preset 4)
Output – General Load
Rated Output Capacity (kVA)1.2/2.0/3.2/4.4/6.810/13/20/2630/36/4858/7286/102
Rated Output Current (A)3/5/8/11/1725/33/49/6575/90/120146/180215/255
Applicable Motor Power (kW)0.4/0.75/1.5/2.2/3.75.5/7.5/11/1519/22/3037/4555/75
Applicable Motor Power (HP)0.5/1/2/3/57.5/10/15/2025/30/4050/6075/100
Overload CapacityAcross columns: At 120% of rated current, can withstand 1 min every 5 min; at 160%, can withstand 3 sec every 25 secAcross columns: At 120% of rated current, can withstand 1 min every 5 min; at 160%, can withstand 3 sec every 25 secAcross columns: At 120% of rated current, can withstand 1 min every 5 min; at 160%, can withstand 3 sec every 25 secAcross columns: At 120% of rated current, can withstand 1 min every 5 min; at 160%, can withstand 3 sec every 25 secAcross columns: At 120% of rated current, can withstand 1 min every 5 min; at 160%, can withstand 3 sec every 25 sec
Max Output Frequency (Hz)599.00599.00400.00
Carrier Frequency (kHz)2~15 (preset 8)2~15 (preset 8)2~10 (preset 6)2~9 (preset 4)2~9 (preset 4)
Input
Input Current (A) – General Load3.9/6.4/12/16/2028/36/52/7283/99/124143/171206/245
Rated Voltage / FrequencyAcross columns: 3-phase 200~240Vac(-15%~+10%), 50/60HzAcross columns: 3-phase 200~240Vac(-15%~+10%), 50/60HzAcross columns: 3-phase 200~240Vac(-15%~+10%), 50/60HzAcross columns: 3-phase 200~240Vac(-15%~+10%), 50/60HzAcross columns: 3-phase 200~240Vac(-15%~+10%), 50/60Hz
Operating Voltage RangeAcross columns: 170~264VacAcross columns: 170~264VacAcross columns: 170~264VacAcross columns: 170~264VacAcross columns: 170~264Vac
Allowed Frequency VariationAcross columns: 47~63HzAcross columns: 47~63HzAcross columns: 47~63HzAcross columns: 47~63HzAcross columns: 47~63Hz
Efficiency (%)97.897.898.298.298.2
Power FactorAcross columns: >0.98Across columns: >0.98Across columns: >0.98Across columns: >0.98Across columns: >0.98
Weight (Kg)2.6±0.35.4±19.8±1.538.5±1.564.8±1.5
Cooling MethodNatural AirNatural AirNatural AirForced AirForced Air
Brake ChopperIncorporatoIncorporatoIncorporatoOptionalOptional
DC ChokeOptionalOptionalOptionalBuilt-in 3%Built-in 3%
EMC FilterOptionalOptionalOptionalOptionalOptional