Delta VFD-B Series Inverter
PARAMETER PRODUK
- Output frequency 0–400 Hz
- Adjustable V/f curve and vector control
- Built-in PID feedback control
Deskripsi
FITUR PRODUK
The Delta VFD-B Series Inverter provides an output frequency range of 0–400 Hz and supports adjustable V/f curves along with vector control, ensuring precise and flexible motor performance for various industrial applications.
It features multi-segment speed programming, built-in PID feedback, automatic torque adjustment, slip compensation, and optional PG card capability for closed-loop speed control, delivering reliable and accurate operation under varying load conditions.
The series includes multiple voltage models, integrated Modbus communication, compatibility with DN-02, LN-01, and PD-01 modules, and a heatsink temperature detection function, enhancing system reliability and durability during continuous industrial use.
BIDANG APLIKASI
| BUILDING AIR CONDITIONING | WOOD CARVING MACHINE | MACHINE TOOL |
|---|---|---|
| WASTEWATER TREATMENT SYSTEM | CRANE X-Y AXIS | WASHING MACHINE |
| FLAT IRONING MACHINE | AIR COMPRESSOR | FREIGHT ELEVATOR |
| ESCALATOR | CIRCULAR LOOM | WEFT KNITTING MACHINE |
| NOODLE MAKING MACHINE | FOUR-SIDED WOOD PLANER | SPINNING MACHINE |
SPESIFIKASI TEKNIS
| 230V SINGLE/THREE-PHASE SERIES | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 150 | 185 | 220 | 300 | 370 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model VFD-B□□□B | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 150 | 185 | 220 | 300 | 370 |
| Applicable Motor Power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 |
| Applicable Motor Power (HP) | 1 | 2 | 3 | 5 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 |
| Rated Output Capacity (kVA) | 1.9 | 2.5 | 4.2 | 6.5 | 9.5 | 12.5 | 18.3 | 24.7 | 28.6 | 34.3 | 45.7 | 55 |
| Rated Output Current (A) | 5 | 7 | 11 | 17 | 25 | 33 | 49 | 65 | 75 | 90 | 120 | 145 |
| Output Frequency Range (Hz) | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 |
| Input Current (A) | 11.9/5.7 | 15.3/7.6 | 22/15.5 | 20.6 | 26 | 34 | 50 | 60 | 75 | 90 | 110 | 142 |
| Rated Voltage / Frequency | 200–240V, 50/60Hz | 200–240V, 50/60Hz | 200–240V, 50/60Hz | 200–240V, 50/60Hz | 200–240V, 50/60Hz | 200–240V, 50/60Hz | 200–240V, 50/60Hz | 200–240V, 50/60Hz | 200–240V, 50/60Hz | 200–240V, 50/60Hz | 200–240V, 50/60Hz | 200–240V, 50/60Hz |
460V THREE-PHASE SERIES
| Model VFD-□□□ B | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 150 | 185 | 220 | 300 | 370 | 450 | 550 | 750 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Output | |||||||||||||||
| Applicable Motor Power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 |
| Applicable Motor Power (HP) | 1 | 2 | 3 | 5 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 |
| Rated Output Capacity (kVA) | 2.3 | 3.2 | 4.2 | 6.5 | 9.5 | 13 | 18.5 | 24.7 | 28.6 | 34.3 | 45.7 | 56 | 69 | 84 | 114 |
| Rated Output Current (A) | 2.7 | 4.2 | 5.5 | 8.5 | 13 | 18 | 24 | 32 | 38 | 45 | 60 | 73 | 91 | 110 | 150 |
| Maximum Output Voltage (V) | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage |
| Output Frequency Range (Hz) | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 |
| Carrier Frequency Range (kHz) | 1–15 | 1–15 | 1–15 | 1–15 | 1–15 | 1–15 | 1–9 | 1–9 | 1–9 | 1–6 | 1–6 | 1–6 | 1–6 | 1–6 | 1–6 |
| Input | |||||||||||||||
| Input Current (A) | 3.2 | 4.3 | 5.9 | 11.2 | 14 | 19 | 25 | 32 | 39 | 49 | 60 | 63 | 90 | 130 | 160 |
| Rated Voltage / Frequency | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz | 3-Phase 380–480V, 50/60Hz |
| Allowable Input Voltage Variation | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) | +10% (42–528V) |
| Allowable Power Frequency Variation | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) | -5% (47–63Hz) |
| Cooling System | Natural | Natural | Natural | Natural | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air |
| Weight (Kg) | 2.7 | 3.2 | 4.5 | 4.5 | 3.2 | 4.5 | 6.8 | 8 | 10 | 13 | 13 | 13 | 13 | 36 | 36 |
575V THREE-PHASE SERIES
| Model VFD-B | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 150 | 185 | 220 | 300 | 370 | 450 | 550 | 750 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Output | |||||||||||||||
| Applicable Motor Power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 |
| Applicable Motor Power (HP) | 1 | 2 | 3 | 5 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 |
| Rated Output Capacity (kVA) | 1.7 | 3.5 | 4.5 | 7.5 | 10 | 13.4 | 18.9 | 21.9 | 26 | 29 | 39 | 40.8 | 51.8 | 61.7 | 75.7 |
| Rated Output Current (A) | 1.7 | 3.5 | 4.5 | 7.5 | 10 | 13.5 | 19 | 22 | 27 | 34 | 41 | 52 | 62 | 80 | 100 |
| Maximum Output Voltage (V) | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage | Corresponding Input Voltage |
| Output Frequency Range (Hz) | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 | 0.1–400 |
| Carrier Frequency Range (kHz) | 1–10 | 1–10 | 1–10 | 1–10 | 1–10 | 1–10 | 1–8 | 1–8 | 1–8 | 1–6 | 1–6 | 1–6 | 1–6 | 1–6 | 1–6 |
| Input | |||||||||||||||
| Input Current (A) | 2.0 | 3.6 | 4.9 | 9.9 | 10.8 | 14.3 | 19 | 22 | 27.7 | 37 | 41 | 52 | 62 | 95 | 117 |
| Rated Voltage / Frequency | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz | 3-Phase 500–600V, 50/60Hz |
| Allowable Input Voltage Variation | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) | -15%~+10% (425–660V) |
| Allowable Power Frequency Variation | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) | ±5% (47–63Hz) |
| Cooling System | Natural | Natural | Natural | Natural | Natural | Natural | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air |
| Weight (Kg) | 2.7 | 3.2 | 4.5 | 6.8 | 8 | 10 | 13 | 13 | 13 | 36 | 36 | 36 | 36 | 50 | 50 |
Pertanyaan Umum
Sebagai perusahaan perdagangan dan manufaktur yang terintegrasi, kami menawarkan rangkaian lengkap catu daya Delta, termasuk catu daya switching, modul daya industri, dan catu daya teregulasi DC, yang cocok untuk otomasi industri dan berbagai peralatan elektronik.
Ya. Kami menyediakan solusi yang disesuaikan berdasarkan kebutuhan pelanggan, termasuk voltase, daya, dan ekstensi fungsional, dengan dukungan teknis profesional untuk memastikan kelayakan.
Kami mengirim melalui layanan logistik dan kurir yang andal, menawarkan pelacakan penuh untuk memastikan produk sampai ke tangan pelanggan dengan aman dan tepat waktu.
Prosesnya sederhana: pilih model → kirimkan persyaratan → konfirmasi solusi → atur pembayaran → pengiriman dan panduan teknis. Kami memberikan dukungan penuh untuk memastikan setiap langkah diselesaikan dengan lancar.
Kami menyediakan garansi asli dari produsen, pasokan suku cadang, panduan pengoperasian, pemeliharaan, dan layanan pemecahan masalah untuk memastikan catu daya Delta beroperasi secara stabil dan andal.