Delta VFD-VE Series Inverter
PARAMÈTRES DU PRODUIT
- Output frequency 0.1–600 Hz
- Robust PDFF servo control
- Zero-speed, high-speed, and low-speed PI gain and frequency bandwidth settings
Description
CARACTÉRISTIQUES DU PRODUIT
The Delta VFD-VE Series Inverter offers a wide output frequency range from 0.1 to 600 Hz and features robust PDFF servo control. It allows zero-speed, high-speed, and low-speed PI gain and frequency bandwidth settings, ensuring precise torque even at zero speed.
With overload capacity up to 150% for one minute and 200% for two seconds, the series supports origin return, pulse following, and 16-point point-to-point position control. It provides position, speed, and torque control modes, strong tension management, and winding/unwinding functions, making it ideal for complex industrial applications.
Equipped with a 32-bit high-speed CPU capable of outputting up to 3333.4 Hz, dual RS-485 support, fieldbus connectivity, spindle positioning, high-speed electric spindle drive, rigid tapping capability, and Windows PC monitoring software for dynamic parameter management, the VFD-VE Series delivers flexible, high-performance solutions for advanced industrial machinery.
CHAMPS D'APPLICATION
| ELEVATOR | OVERHEAD CRANE | HOIST |
|---|---|---|
| PCB DRILLING MACHINE | ENGRAVING MACHINE | STEEL & METALLURGY |
| PETROLEUM | CNC MACHINE TOOL | INJECTION MOLDING MACHINE |
| AUTOMATED STORAGE SYSTEM | PRINTING MACHINERY | REWINDING MACHINE |
| SLITTING MACHINE |
SPÉCIFICATIONS TECHNIQUES
230V Series
| Voltage Level | 230V Class | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 185 | 220 | 220 | 300 | 370 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Output Control | Model VFD-XXXV | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 185 | 220 | 220 | 300 | 370 |
| Output Control | Rated Output Power (kVA) | 1.9 | 2.7 | 4.2 | 6.5 | 9.5 | 13 | 19 | 29 | 34 | 34 | 46 | 55 |
| Output Control | Rated Output Current (A) | 5.0 | 7.5 | 11 | 17 | 25 | 33 | 49 | 75 | 90 | 90 | 120 | 146 |
| Output Control | Applicable Motor Power (kW) | 1.0 | 2.0 | 3.0 | 5.0 | 7.5 | 10 | 15 | 25 | 30 | 30 | 40 | 50 |
| Output Control | Applicable Motor Power (HP) | 1.0 | 2.0 | 3.0 | 5.0 | 7.5 | 10 | 15 | 25 | 30 | 30 | 40 | 50 |
| Output Control | Transformer Output Current (A) | 6.25 | 9.6 | 13 | 21 | 31 | 45 | 61 | 93 | 112 | 112 | 150 | 182 |
| Output Control | Applicable Motor Power (HP) | 1.5 | 2.5 | 4 | 7.5 | 10 | 15 | 20 | 30 | 40 | 40 | 50 | 60 |
| Output Control | Maximum Output Voltage (V) | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage |
| Output Control | Output Frequency Range (Hz) | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz | 0.00~600.0Hz |
| Output Control | Input Current (A) | 6.4 | 9.9 | 15 | 21 | 25 | 33 | 49 | 63 | 68 | 79 | 106 | 125 |
| Output Control | Allowable Input Voltage | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz | Three-phase, 200-240V, 50/60Hz |
| Output Control | Allowable Input Voltage Variation | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) | ±10%(180~264V) |
| Output Control | Allowable Power Frequency Variation | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) |
| Output Control | Cooling Method | Natural Air Cooling | Natural Air Cooling | Natural Air Cooling | Natural Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling |
| Output Control | Weight (kg) | 2.7 | 3.2 | 4.5 | 6.8 | 8 | 10 | 13 | 13 | 13 | 13 | 36 | 36 |
460V Series
| 460V Series | Voltage Level | 460V Class | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 150 | 185 | 220 | 300 | 370 | 450 | 550 | 750 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Sortie | Model VFD-XXXV | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 150 | 185 | 220 | 300 | 370 | 450 | 550 | 750 | |
| Sortie | Rated Output Power (kVA) | 2.3 | 3.2 | 4.2 | 6.3 | 9.9 | 14 | 18 | 24 | 29 | 34 | 48 | 56 | 69 | 80 | 100 | |
| Sortie | Rated Output Current (A) | 3.0 | 4.2 | 6.0 | 8.5 | 13 | 18 | 24 | 32 | 38 | 45 | 60 | 73 | 91 | 110 | 150 | |
| Sortie | Applicable Motor Power (HP) | 1.0 | 2.0 | 3.0 | 5.0 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | |
| Sortie | Transformer Output Current (A) | 3.8 | 5.3 | 7.5 | 10 | 18 | 22 | 30 | 40 | 47 | 56 | 75 | 91 | 113 | 138 | 188 | |
| Sortie | Applicable Motor Power (HP) | 1.5 | 2.5 | 4 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | 125 | |
| Sortie | Maximum Output Voltage (V) | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | Three-phase corresponding input voltage | |
| Sortie | Output Frequency Range (Hz) | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | 0.00~600.00Hz | |
| Power | Input Current (A) | Three-phase 380~480V | 4.0 | 5.8 | 7.4 | 9.9 | 12 | 17 | 25 | 27 | 35 | 42 | 56 | 67 | 87 | 101 | 122 |
| Power | Allowable Input Voltage | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | Three-phase, 380~480V | |
| Power | Allowable Input Voltage Variation | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | ±10%(342~528V) | |
| Power | Allowable Power Frequency Variation | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | ±5%(47~63Hz) | |
| Power | Cooling Method | Natural Air Cooling | Natural Air Cooling | Natural Air Cooling | Natural Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | |
| Power | Weight (kg) | 2.7 | 3.2 | 4.5 | 6.8 | 8 | 10 | 13 | 13 | 13 | 13 | 36 | 36 | 36 | 50 | 50 |
FAQ
En tant qu'entreprise intégrée de commerce et de fabrication, nous offrons une gamme complète d'alimentations Delta, y compris des alimentations à découpage, des modules d'alimentation industriels et des alimentations régulées CC, adaptées à l'automatisation industrielle et à divers équipements électroniques.
Oui. Nous fournissons des solutions personnalisées basées sur les exigences du client, y compris la tension, la puissance et les extensions fonctionnelles, avec une assistance technique professionnelle pour garantir la faisabilité.
Nous expédions nos produits par l'intermédiaire de services logistiques et de messagerie fiables, offrant un suivi complet pour garantir que les produits parviennent aux clients en toute sécurité et dans les délais impartis.
Le processus est simple : sélectionner le modèle → soumettre les exigences → confirmer la solution → organiser le paiement → livraison et conseils techniques. Nous fournissons une assistance complète pour garantir le bon déroulement de chaque étape.
Nous offrons la garantie du fabricant d'origine, la fourniture de pièces de rechange, des conseils d'utilisation, des services de maintenance et de dépannage afin de garantir un fonctionnement stable et fiable des blocs d'alimentation Delta.