Delta AX-3 Series Motion Control CPU - Contrôleur polyvalent à haute fonctionnalité
PARAMÈTRES DU PRODUIT
- 8-axis EtherCAT motion control with 2 ms minimum synchronization
- IEC 61131-compliant CODESYS integrated development platform
- Flexible I/O expansion and multiple device connectivity
- Supports IEC 61131-3 programming languages and OPC UA server integration
Description
CARACTÉRISTIQUES DU PRODUIT
8-axis EtherCAT motion controller with minimum synchronization time of 2 ms.
Integrated CODESYS development platform compliant with IEC 61131 standards, consolidating automation requirements across devices.
Supports existing AS I/O modules, reducing additional configuration costs and enabling flexible expansion.
*Multiple interfaces including Ethernet 2, RS-485, RS-232, and encoder inputs, allowing connection with various devices.
Integrated development environment allows configuration of motion axes on a single platform, offering motion control planning tools, PLCopen MC standard function blocks, E-CAM editor, positioning planning, and visualization tools.
Supports IEC 61131-3 international programming languages (FBD, LD, ST, SFC, CFC), accommodating diverse development methods.
Supports OPC UA (Server) without requiring an additional OPC UA gateway for connecting to information management systems.
CHAMPS D'APPLICATION
| Wood Processing | Packaging | Printing |
|---|---|---|
| Textile | Pharmaceutical |
SPÉCIFICATIONS TECHNIQUES
| Category | Specifications |
|---|---|
| Motion Control Network | AX-308E: EtherCAT (100 Mbps) |
| Synchronous Axes / Time | Up to 16 axes (real + virtual + pulse axes) 8 axes / 2 ms, max 8 real axes (EtherCAT) Up to 4 pulse axes |
| Electronic Cam Function | Number of cam tables: 80 Max points per cam table: 256 |
| Program / Performance | Program capacity: 8 MB Variable capacity (with power-off retention): 768 kb Variable capacity (without power-off retention): 16 MB LD instruction execution time: 5 ns Arithmetic instruction (LREAL): 36 ns |
| Communication Interface | Mini USB(2.0) / RS232 / RS485 x1 each 2 Ethernet ports, supporting Modbus TCP (Server + Client = 32) and EtherNet/IP (Scanner/Adapter), Scanner supports up to 8 Adapters |
| I/O Interface | 2 incremental encoder interfaces + 1 SSI absolute encoder interface 6 high-speed counters (200 kHz) 4 pulse outputs (200 kHz) Max I/O expansion: Input 8,192 bytes / Output 8,192 bytes Max expansion modules: 32 (analog: 16) |
| Additional Features | Built-in Micro SD slot Built-in RTC (requires CR1620 3V battery) |
FAQ
En tant qu'entreprise intégrée de commerce et de fabrication, nous offrons une gamme complète d'alimentations Delta, y compris des alimentations à découpage, des modules d'alimentation industriels et des alimentations régulées CC, adaptées à l'automatisation industrielle et à divers équipements électroniques.
Oui. Nous fournissons des solutions personnalisées basées sur les exigences du client, y compris la tension, la puissance et les extensions fonctionnelles, avec une assistance technique professionnelle pour garantir la faisabilité.
Nous expédions nos produits par l'intermédiaire de services logistiques et de messagerie fiables, offrant un suivi complet pour garantir que les produits parviennent aux clients en toute sécurité et dans les délais impartis.
Le processus est simple : sélectionner le modèle → soumettre les exigences → confirmer la solution → organiser le paiement → livraison et conseils techniques. Nous fournissons une assistance complète pour garantir le bon déroulement de chaque étape.
Nous offrons la garantie du fabricant d'origine, la fourniture de pièces de rechange, des conseils d'utilisation, des services de maintenance et de dépannage afin de garantir un fonctionnement stable et fiable des blocs d'alimentation Delta.