{"id":2739,"date":"2025-12-19T05:54:55","date_gmt":"2025-12-19T05:54:55","guid":{"rendered":"https:\/\/www.leadeverfuture.com\/?post_type=wpkj_product&#038;p=2739"},"modified":"2025-12-19T05:54:58","modified_gmt":"2025-12-19T05:54:58","slug":"delta-rtu-cn01-canopen-communication-device","status":"publish","type":"wpkj_product","link":"https:\/\/www.leadeverfuture.com\/de\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/","title":{"rendered":"Delta RTU-CN01 CANopen Communication Device"},"content":{"rendered":"<h2 id=\"gspb_heading-id-gsbp-ddbebef\" class=\"gspb_heading gspb_heading-id-gsbp-ddbebef\">PRODUKTMERKMALE<\/h2>\n\n\n\n<p><strong>The Delta RTU-CN01 is a high-performance CANopen communication device designed for seamless integration with DVP-Slim right-side expansion modules.<\/strong><\/p>\n\n\n\n<p><strong>It supports up to 128 input and output points per module and can connect up to 14 digital and special expansion modules, including up to 8 special modules such as analog and temperature modules.<\/strong><\/p>\n\n\n\n<p><strong>The network configuration software provides a graphical interface, automatically scans and identifies expansion modules, allows flexible configuration of control registers (CR) for I\/O data, sets error handling rules, and diagnoses module errors.<\/strong><\/p>\n\n\n\n<p><strong>When disconnected from the master station, users can choose to maintain previous output values or set all digital and special module outputs to zero.<\/strong><\/p>\n\n\n\n<p><strong>Compliant with CANopen DS301 V4.02 protocol, the device supports NMT services, Heartbeat Protocol for error control, PDO services with up to 8 TxPDO and 8 RxPDO, synchronous and asynchronous PDO transmission, and SDO services.<\/strong><\/p>\n\n\n\n<p><strong>Compact, robust, and user-friendly, the RTU-CN01 ensures stable, flexible, and scalable CANopen network management for industrial automation systems.<\/strong><\/p>\n\n\n\n<h2 id=\"gspb_heading-id-gsbp-8bc1aab\" class=\"gspb_heading gspb_heading-id-gsbp-8bc1aab\">TECHNISCHE DATEN<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parameter<\/th><th>Spezifikation<\/th><\/tr><\/thead><tbody><tr><td>Slim Right-side Expansion Module<\/td><td>Supports up to 128 points for input and output<\/td><\/tr><tr><td>Maximum Modules<\/td><td>Up to 14 DVP-Slim digital and special modules, with a maximum of 8 special modules (including analog and temperature modules)<\/td><\/tr><tr><td>Network Configuration Software<\/td><td>Provides graphical configuration interface, auto-scans and detects expansion modules, allows arbitrary assignment of control registers (CR) for I\/O data, sets error handling, and diagnoses module errors<\/td><\/tr><tr><td>Disconnection Behavior<\/td><td>User can choose special module output and digital module output to retain previous values or reset to zero when disconnected from the main station<\/td><\/tr><tr><td>CANopen Standard<\/td><td>Compliant with DS301 V4.02<\/td><\/tr><tr><td>Network Management<\/td><td>Supports NMT service<\/td><\/tr><tr><td>Error Control Protocol<\/td><td>Supports Heartbeat Protocol<\/td><\/tr><tr><td>PDO Services<\/td><td>Up to 8 TxPDO and 8 RxPDO<\/td><\/tr><tr><td>PDO Transmission Type<\/td><td>Supports asynchronous, synchronous cyclic, synchronous acyclic<\/td><\/tr><tr><td>SDO Services<\/td><td>Unterst\u00fctzt<\/td><\/tr><\/tbody><\/table><\/figure>","protected":false},"excerpt":{"rendered":"<p>The Delta RTU-CN01 is a high-performance CANopen communication device designed for seamless integration with DVP-Slim right-side expansion modules. It supports up to 128 input and output points per module and can connect up to 14 digital and special expansion modules, including up to 8 special modules such as analog and temperature modules. The network configuration [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2740,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"product_cat":[39],"product_tag":[],"class_list":["post-2739","wpkj_product","type-wpkj_product","status-publish","has-post-thumbnail","hentry","product_cat-network-solutions"],"blocksy_meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Delta RTU-CN01 CANopen Communication Device - Delta Power Supply Solutions, Industrial Switching, UPS &amp; Modular Power \u2013 Machine Stable<\/title>\n<meta name=\"description\" content=\"The Delta RTU-CN01 CANopen device supports DVP-Slim modules with up to 128 I\/O points per module, connects 14 expansion modules, provides NMT, PDO, SDO services, Heartbeat error control, and graphical network configuration for industrial automation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.leadeverfuture.com\/de\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Delta RTU-CN01 CANopen Communication Device - Delta Power Supply Solutions, Industrial Switching, UPS &amp; Modular Power \u2013 Machine Stable\" \/>\n<meta property=\"og:description\" content=\"The Delta RTU-CN01 CANopen device supports DVP-Slim modules with up to 128 I\/O points per module, connects 14 expansion modules, provides NMT, PDO, SDO services, Heartbeat error control, and graphical network configuration for industrial automation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.leadeverfuture.com\/de\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/\" \/>\n<meta property=\"og:site_name\" content=\"Delta Power Supply Solutions, Industrial Switching, UPS &amp; Modular Power \u2013 Machine Stable\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-19T05:54:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.leadeverfuture.com\/wp-content\/uploads\/2025\/12\/delta-rtu-cn01-canopen-device.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"360\" \/>\n\t<meta property=\"og:image:height\" content=\"306\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"2\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/\",\"url\":\"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/\",\"name\":\"Delta RTU-CN01 CANopen Communication Device - Delta Power Supply Solutions, Industrial Switching, UPS &amp; Modular Power \u2013 Machine Stable\",\"isPartOf\":{\"@id\":\"https:\/\/www.leadeverfuture.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.leadeverfuture.com\/wp-content\/uploads\/2025\/12\/delta-rtu-cn01-canopen-device.jpg\",\"datePublished\":\"2025-12-19T05:54:55+00:00\",\"dateModified\":\"2025-12-19T05:54:58+00:00\",\"description\":\"The Delta RTU-CN01 CANopen device supports DVP-Slim modules with up to 128 I\/O points per module, connects 14 expansion modules, provides NMT, PDO, SDO services, Heartbeat error control, and graphical network configuration for industrial automation.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/#primaryimage\",\"url\":\"https:\/\/www.leadeverfuture.com\/wp-content\/uploads\/2025\/12\/delta-rtu-cn01-canopen-device.jpg\",\"contentUrl\":\"https:\/\/www.leadeverfuture.com\/wp-content\/uploads\/2025\/12\/delta-rtu-cn01-canopen-device.jpg\",\"width\":360,\"height\":306},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\/\/www.leadeverfuture.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4ea7\u54c1\",\"item\":\"https:\/\/www.leadeverfuture.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Delta RTU-CN01 CANopen Communication Device\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.leadeverfuture.com\/#website\",\"url\":\"https:\/\/www.leadeverfuture.com\/\",\"name\":\"Delta Power Supply Solutions, Industrial Switching, UPS & Modular Power \u2013 Machine Stable\",\"description\":\"Comprehensive Industrial Power Solutions with Integration, Customization, and Technical Support\",\"publisher\":{\"@id\":\"https:\/\/www.leadeverfuture.com\/#\/schema\/person\/b6097a7f514d128279e1a156312166d2\"},\"alternateName\":\"Machine Stable\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.leadeverfuture.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\/\/www.leadeverfuture.com\/#\/schema\/person\/b6097a7f514d128279e1a156312166d2\",\"name\":\"deltaadministrator\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/www.leadeverfuture.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/www.leadeverfuture.com\/wp-content\/uploads\/2025\/12\/leadever-future-logo-3.png\",\"contentUrl\":\"https:\/\/www.leadeverfuture.com\/wp-content\/uploads\/2025\/12\/leadever-future-logo-3.png\",\"width\":300,\"height\":49,\"caption\":\"deltaadministrator\"},\"logo\":{\"@id\":\"https:\/\/www.leadeverfuture.com\/#\/schema\/person\/image\/\"},\"sameAs\":[\"https:\/\/www.leadeverfuture.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Delta RTU-CN01 CANopen Communication Device - Delta Power Supply Solutions, Industrial Switching, UPS &amp; Modular Power \u2013 Machine Stable","description":"The Delta RTU-CN01 CANopen device supports DVP-Slim modules with up to 128 I\/O points per module, connects 14 expansion modules, provides NMT, PDO, SDO services, Heartbeat error control, and graphical network configuration for industrial automation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.leadeverfuture.com\/de\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/","og_locale":"de_DE","og_type":"article","og_title":"Delta RTU-CN01 CANopen Communication Device - Delta Power Supply Solutions, Industrial Switching, UPS &amp; Modular Power \u2013 Machine Stable","og_description":"The Delta RTU-CN01 CANopen device supports DVP-Slim modules with up to 128 I\/O points per module, connects 14 expansion modules, provides NMT, PDO, SDO services, Heartbeat error control, and graphical network configuration for industrial automation.","og_url":"https:\/\/www.leadeverfuture.com\/de\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/","og_site_name":"Delta Power Supply Solutions, Industrial Switching, UPS &amp; Modular Power \u2013 Machine Stable","article_modified_time":"2025-12-19T05:54:58+00:00","og_image":[{"width":360,"height":306,"url":"https:\/\/www.leadeverfuture.com\/wp-content\/uploads\/2025\/12\/delta-rtu-cn01-canopen-device.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"2\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/","url":"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/","name":"Delta RTU-CN01 CANopen Communication Device - Delta Power Supply Solutions, Industrial Switching, UPS &amp; Modular Power \u2013 Machine Stable","isPartOf":{"@id":"https:\/\/www.leadeverfuture.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/#primaryimage"},"image":{"@id":"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/#primaryimage"},"thumbnailUrl":"https:\/\/www.leadeverfuture.com\/wp-content\/uploads\/2025\/12\/delta-rtu-cn01-canopen-device.jpg","datePublished":"2025-12-19T05:54:55+00:00","dateModified":"2025-12-19T05:54:58+00:00","description":"The Delta RTU-CN01 CANopen device supports DVP-Slim modules with up to 128 I\/O points per module, connects 14 expansion modules, provides NMT, PDO, SDO services, Heartbeat error control, and graphical network configuration for industrial automation.","breadcrumb":{"@id":"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/#primaryimage","url":"https:\/\/www.leadeverfuture.com\/wp-content\/uploads\/2025\/12\/delta-rtu-cn01-canopen-device.jpg","contentUrl":"https:\/\/www.leadeverfuture.com\/wp-content\/uploads\/2025\/12\/delta-rtu-cn01-canopen-device.jpg","width":360,"height":306},{"@type":"BreadcrumbList","@id":"https:\/\/www.leadeverfuture.com\/products\/control-products\/network-solutions\/delta-rtu-cn01-canopen-communication-device\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.leadeverfuture.com\/"},{"@type":"ListItem","position":2,"name":"\u4ea7\u54c1","item":"https:\/\/www.leadeverfuture.com\/products\/"},{"@type":"ListItem","position":3,"name":"Delta RTU-CN01 CANopen Communication Device"}]},{"@type":"WebSite","@id":"https:\/\/www.leadeverfuture.com\/#website","url":"https:\/\/www.leadeverfuture.com\/","name":"Delta Stromversorgungsl\u00f6sungen, Industrielles Schalten, UPS &amp; Modular Power - Machine Stable","description":"Umfassende industrielle Stromversorgungsl\u00f6sungen mit Integration, kundenspezifischer Anpassung und technischem Support","publisher":{"@id":"https:\/\/www.leadeverfuture.com\/#\/schema\/person\/b6097a7f514d128279e1a156312166d2"},"alternateName":"Machine Stable","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.leadeverfuture.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":["Person","Organization"],"@id":"https:\/\/www.leadeverfuture.com\/#\/schema\/person\/b6097a7f514d128279e1a156312166d2","name":"deltaadministrator","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.leadeverfuture.com\/#\/schema\/person\/image\/","url":"https:\/\/www.leadeverfuture.com\/wp-content\/uploads\/2025\/12\/leadever-future-logo-3.png","contentUrl":"https:\/\/www.leadeverfuture.com\/wp-content\/uploads\/2025\/12\/leadever-future-logo-3.png","width":300,"height":49,"caption":"deltaadministrator"},"logo":{"@id":"https:\/\/www.leadeverfuture.com\/#\/schema\/person\/image\/"},"sameAs":["https:\/\/www.leadeverfuture.com"]}]}},"acf":{"_product_image_gallery":[2740],"_product_excerpt":"<ul>\r\n \t<li data-start=\"1937\" data-end=\"2014\">Connects up to 14 DVP-Slim expansion modules with 128 I\/O points per module<\/li>\r\n \t<li data-start=\"2017\" data-end=\"2099\">Supports CANopen DS301 V4.02 protocol with NMT, PDO, SDO, and Heartbeat services<\/li>\r\n \t<li data-start=\"2102\" data-end=\"2200\">Graphical network configuration software with module scanning, CR mapping, and error diagnostics<\/li>\r\n \t<li data-start=\"2203\" data-end=\"2290\">Maintains output values on disconnection or sets outputs to zero for flexible control<\/li>\r\n<\/ul>","post_download_file":""},"_links":{"self":[{"href":"https:\/\/www.leadeverfuture.com\/de\/wp-json\/wp\/v2\/wpkj_product\/2739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leadeverfuture.com\/de\/wp-json\/wp\/v2\/wpkj_product"}],"about":[{"href":"https:\/\/www.leadeverfuture.com\/de\/wp-json\/wp\/v2\/types\/wpkj_product"}],"author":[{"embeddable":true,"href":"https:\/\/www.leadeverfuture.com\/de\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":1,"href":"https:\/\/www.leadeverfuture.com\/de\/wp-json\/wp\/v2\/wpkj_product\/2739\/revisions"}],"predecessor-version":[{"id":2741,"href":"https:\/\/www.leadeverfuture.com\/de\/wp-json\/wp\/v2\/wpkj_product\/2739\/revisions\/2741"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/www.leadeverfuture.com\/de\/wp-json\/wp\/v2\/media\/2740"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.leadeverfuture.com\/de\/wp-json\/wp\/v2\/media\/2740"}],"wp:attachment":[{"href":"https:\/\/www.leadeverfuture.com\/de\/wp-json\/wp\/v2\/media?parent=2739"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.leadeverfuture.com\/de\/wp-json\/wp\/v2\/product_cat?post=2739"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.leadeverfuture.com\/de\/wp-json\/wp\/v2\/product_tag?post=2739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}